UL94 Flammability Chamber
UL94 Flammability Chamber
- Conforms to UL94 and IEC requirements for the classification of plastics
- Draft free chamber with a volume greater than 1m3
- Integral comprehensive control panel
- ASTM D5025 burner with wing tip and adjustable burner angle
- Ergonomically designed access ports for sample and burner positioning
- Large counterbalanced sliding door allowing complete access
- Can be customised to include other tests such as FAR Part 25
Instrument Specialists STA
Simultaneous Thermal Analyzer
- 0.1µg balance resolution
- Vertical thermobalance system
- True simultaneous DSC/TGA
- -125 to 650C, 1000C and 1500C user exchangeable furnaces
- Optimized for evolved gas analysis
- Fast heating and cooling rates
- High resolution electronics with USB communications
- Infinity pro software with advanced analysis feature
Instrument Specialists TMA
Thermomechanical Analyzer
- Based on the proven vertical performance design utilizing an Oil Float Suspension System
- Operates over a wide temperature range and under a range of modes to provide superior performance
- Simple, easy-to-use, rugged thermomechanical analyzer ideal for multiple measurements
- Height-to-width aspect ratio enables accurate measurements of any size sample from a few microns to a centimeter tall or more
In Stock and Ready to Ship!
In Stock and Ready to SHIP!
Windows 10 ready Thermal Analyzers
Mettler Toledo DSC 1; fan cooling option
Mettler Toledo DMA 1 with LN2 option
Mettler Toledo DSC/TGA 1
TA Instruments Q2000 DSC with RCS90 cooling unit
TA Instruments Q200 DSC
TA Instruments Q400 TMA
TA instruments Q5000IR TGA
TA Instruments Q500
Perkin Elmer 8500 DSC
Perkin Elmer 8000 DMA
Hitachi STA 7200 TGA/DSC
Hitachi DSC 7000X
Seiko DMA 6100
Windows 10 ready Rheometers
Thermo Fisher Mars III Advanced Modular Rheometer
Thermo Fisher RS 6000 Rheometer
Thermo Fisher RS 600 Rheometer
TA Instruments AR G2
Ta instruments AR 2000EX
TA Instruments Ares Rheometer
All instruments have been fully evaluated and certified by our knowledgeable staff.
RT Instruments has over 800 thermal and rheology instruments on-hand.
If you do not see what you are looking for on the list, or require more information please contact us at:
RT Instruments Inc.
530-666-6700 or [email protected]
Sample Testing Services
Are your laboratory capabilities over capacity?
Do you need added throughput for sample testing?
RT Instruments, Inc. is here to help quick and efficient turn-around!
RT Instruments, Inc. has commissioned several Thermal, Rheology, FTIR, GC/MS, UV/VIS, HPLC, Karl Fisher, Ion Chromatography, Accelerated Rate Calorimeter, Laser Defractive Particle Size instruments to help you catch up or just get ahead.
Whether it be QA, Research Discovery, etc., we can help!
Contact RT Instruments, Inc. for details
Project or batch pricing also available
Equinox Semi-Micro and Analytical Balances
Features
- Large 5’’ 800×480 pixel touchscreen display
- Level indicator and adjustable feet ensure proper balance
setup for optimum weighing results - RS-232 interface is available to provide speedy connection
to computers and printers - USB host for memory card and USB I/O interface
- Built-in memory for storing products and settings
- Printouts include date and time for data tracking within
Good Laboratory Practices (GLP) guidelines - Multilingual display permits use in various regions
- Checkweighing with audible alarm
General Specifications
- Weighing units: g, mg, ct, GN, lb, oz, dwt, mm, ozt, tl.H, tl.S, tl.T, T, custom unit
- Interface: RS-232 / USB
- Power Supply: 24V 50/60Hz 500mA adapter
- Display: Touchscreen with 4.9″/ 125mm -high digits
- Calibration: Internal automatic calibration / External calibration
- Housing: ABS plastic
- Operating Temperature: 10° to 30°C / 50° to 86°F
Applications
- Checkweighing
- Parts Counting
- Density Determination
- Percentage Weighing
- Statistics
- Dynamic/Animal Weighing
- Formulation
- Weighing
- Textile
Solis Semi-Micro and Analytical Balances
Features
- High-resolution graphic display
- Level indicator and adjustable feet ensure proper
balance setup for optimum weighing results - RS-232 interface is available to provide speedy
connection to computers and printer - Printouts include date and time for data tracking
within Good Laboratory Practices (GLP) guidelines - Multilingual display permits use in various regions
- Checkweighing with audible alarm
General Specifications
- Weighing units: g, mg, lb, oz, ct, GN, dwt, mm, ozt, T, tl.H, tl.S, tl.T, custom unit
- Interface: RS-232
- Power Supply: 24V 50/60Hz 500mA adapter
- Display: Graphic display with 0.6″ -high digits
- Calibration: Internal automatic calibration / External calibration
- Housing: ABS plastic
- Operating Temperature: 10° to 30°C / 50° to 86°F
Applications
- Checkweighing
- Parts Counting
- Density Determination
- Percentage Weighing
- Dynamic/Animal Weighing
- Formulation/Recipe
- Weighing
Thickness Gauges
Thickness Gauge EV 01
The EV 01 Thickness Gauge is intended for rubber or plastic thickness measurement according to ISO 23529 and compression set measurement according to ISO 815.
Thickness Gauge EV 06
The EV 06 Thickness Gauge is intended for textile thickness measurement according to ISO 5084. Available in two versions: EV 06A 0,1 and EV 06B.
Pneumatic Thickness Gauge EV 07B
The EV 07B Pneumatic Thickness Gauge is intended for textile thickness measurement according to ISO 5084.
Thickness Gauge EV 01F
Thickness Gauge EV 01 F is a special version, with the possibility to set the parallelity between measuring foot and table.
Oxygen Index Module
Oxygen Index Module
- Digital touchscreen display showing oxygen concentration, gas flow rate through the chimney, chimney temperature and lapsed time during the test
- Oxygen concentration selected and instrument adjusts automatically
- AutoCal facility calibrates zero and span range totally automatically
- Fast response O2 transducer accurate to +/- 0.1 %
Temperature Index Module
Temperature Index Module
- The Temperature Index extends the range of the Oxygen Index Module, so that the oxygen index of materials can be measured at elevated temperatures
- Generally, the oxygen index falls as the gas mixture is heated, so work at elevated temperatures supplements work carried out at room temperature
- This new model utilises the very latest control technology.
- Selection of all variable elements is by easy to use touchscreen and the intelligent system adjusts accordingly
- This differs from most competitive products, where valves need to be adjusted manually, which is a time consuming and a tedious task
NBS Smoke Chamber
NBS Smoke Chamber
- Intelligent ‘hot swappable’ design, conforming to BS6401/ASTM E662 and ISO5659-2, or available configured to either test arrangement
- Vertical orientation is used for FAA testing
- ISO 5659-2 horizontal configuration used in new marine and railway applications
- Can be utilised for toxicity measurements according to the latest Boeing and Airbus test standards, including AITM 3.0005 issue 2
- Digital PMT light measurement system
- User-friendly, customer-configurable Windows 10 software
Cone Calorimeter
Cone Calorimeter
- Weighing system: resolution better than +/-0.01
- Computerized calibration of O2, CO/CO2 analyzer together with hydrocarbon measurement
- Stores preset heat flux levels and can send them to the controller for testing at various levels
- Brings together the analyzer and DAQ components into a single package
- Windows 10 computer with 27” HD Monitor
- During test, all data channels are displayed together with elapsed time, ignition, flameout, rate of heat release and time averaged heat release, smoke level and duct flow
Click here for more information
Horizontal Flammability Chamber
Horizontal Flammability Chamber
- Bespoke ignition source according to ISO 3795
- Automatic starting of test when sample holder is placed in test position
- Selectable and automated flame application time
- Enables ‘after flame’ and ‘dripping’ timings to be recorded
- Also complies with FMVSS 302 automotive testing
- Can be used for non-certified FAR horizontal flammability testing
Ignitability Chamber
Ignitability Chamber
- EN ISO 11925-2 is relevant to material classes C, D and E for Euroclass testing
- All high-quality stainless-steel construction throughout
- External burner positioning from front
- External lateral positioning of specimen holder during testing, also from front
- Bespoke ignition source according to the above standard
- Also complies with DIN 4102 Part 1 class B2 small burner test and NF P 92-504.
FAA 4C Flammability Chamber
FAA 4C Flammability Chamber
- Test chambers according to FAR Part 25; vertical, horizontal, 45°/60° tests
- Stainless steel construction
- Adjustable burner position from front
- Automatic starting of test when burner is placed in test position
- Selectable and automated flame application time
- Enables ‘after flame’ and ‘dripping’ timings to be recorded